رسائل ماجيستير
English
2014
Performance Evaluation Of Corrosion Inhibitors For Local Conditions performance Evaluation Of Corrosion Inhibitors For Local Conditions
Omar S. Baghabra Al-Amoudi, Mohammed Maslehuddin, خالد أحمد علوي السوداني
كلية الهندسة-جامعة الملك فهد للبترول والمعادن · السعودية
Deterioration of concrete structures due to reinforcement corrosion is noted in many industrial and non-industrial structures in the coastal areas of Saudi Arabia. Considerable resources are being expended to repair and rehabilitate the deteriorated concrete structures. While deteriorating concrete structures need to be repaired for meeting their design life, preventive measures need also to be taken to avoid deterioration in new construction. Some of the protective measures include: use of fusion-bonded-epoxy coated (FBEC) bars or chemical inhibitors. However, under severe exposure conditions, the service life of structures built with FBEC steel bars can be limited due to the detrimental effect of damage to the FBEC. Consequently, there is an increasing trend towards utilizing corrosion inhibitors to minimize reinforcement corrosion.Though there is some information on the use of corrosion inhibitors, both locally and in other countries, several aspects, such as the exposure temperature and the combined presence of chloride and sulfate ions, on the effectiveness of inhibitors have not been studied. Consequently, there is an urgent need to study the performance of inhibitors in the presence of temperature and chloride and sulfate concentration.This research program was conducted into two parts. The first part consisted of preparing a set of 66 steel specimens immersed in simulated concrete pore solution and varying the three key exposure parameters (chloride and/or sulfate concentration, inhibitor type and exposure temperature) using potentio-dynamic polarization method. In the second part of this research, a set of 36 mixtures of concrete specimens was prepared to evaluate the performance of the selected inhibitors in both sound and cracked concrete specimens according to ASTM G 109.Potentio-dynamic polarization results showed that all the inhibitors perform well in minimizing corrosion. However, their performance decreased with increasing the chloride and/or sulfate concentration and exposure temperature. The corrosion in ASTM G 109 uncracked specimens with the selected corrosion inhibitors was less than that in the control specimens (around three to four times lower). Further, in case of cracked concrete specimens, Inhibitor IV and Inhibitor V exhibited the best corrosion protection. However, the specimens incorporating Inhibitors I, II and III provided no or at best limited protection to the reinforcing steel. The data developed in this study were used in the selection of appropriate inhibitors for the local conditions.