Schoobrary رجوع
العودة إلى البحث
رسائل ماجيستير الانجليزية 2013 fef20bf6-39e7-46c0-8588-4abdf87ab3b7

Energy Optimization and Retrofit of Heat Exchanger Networks Case Study: Preheat-Train of the Crude Distillation Unit

Manal Awad Mohammed Ibrahim, Abdelbagi Osman Elsiddig Mustafa

كلية الهندسة والتكنولوجيا-جامعة الجزيرة · السودان

الموضوعات

علوم تطبيقية وتكنولوجية

الملخص

Energy conservation and its efficient usage in chemical process industries become the most debated issue considered worldwide due to the current energy crisis. This study is featuring energy optimization and retrofit for the Pre-heat Train heat exchanger network (HEN) of the crude distillation unit. The recent developed combinatorial approach of Paths Combination has been applied for such HEN to generate several energy retrofit options. Energy conservation was conducted by the means of utilizing heat shifting to reduce the energy consumption using each of the generated options. The heat shifting processwhich based on the (+/-) principle of pinch technology has been achieved using a simple developed Dev- C++computer programme. Heat shifting was conductedwhilekeeping a constant heat recovery approach temperature difference (HRAT) between hot and cold HEN streams. Shifting the heat from HEN utilities implies increasing the heat recovery between the processes’ streams. The penalty of increasing the heat recovery is to increase the heat transfer area for each of the affected exchanger in HEN without any topological modification. The obtained results had been analyzed economically to facilitate the decision of picking the most optimum retrofit solution. It was found that most of the generated options are located in the feasible zone of the HEN retrofit. Some of these options have showed a reduction in energy consumption in the range of 4964kW to save about 318K$/yr with 268K$ as penalty of capital investment to be returned within less than 1 year payback. The study recommended that the Dev-C++programming code which built for the heat shifting process in this study could be developed further to be adopted by ASPEN Plus Technology.

التعريف والنوع

رقم الوثيقة
fef20bf6-39e7-46c0-8588-4abdf87ab3b7
رقم العقد
0
نوع الوسائط
Crawler
نوع المحتوى
الرسائل العلمية
صيغة المصدر
رسائل ماجيستير
نوع الملف
pdf text
أسماء الملفات
72347_1.pdf

بيانات النشر

ألقاب المؤلفين
[{"name_ar":" Manal Awad Mohammed Ibrahim","title_ar":"اعداد","title_en":"Preparation"},{"name_ar":"Abdelbagi Osman Elsiddig Mustafa ","title_ar":"اشراف","title_en":"Supervision"}]
اللغة
English

المصدر والدورية

اسم المصدر
Energy Optimization and Retrofit of Heat Exchanger Networks Case Study: Preheat-Train of the Crude Distillation Unit

المحتوى والصفحات

عدد الصفحات
0

إشراف وإعداد

الإشراف
Abdelbagi Osman Elsiddig Mustafa
الإعداد
Manal Awad Mohammed Ibrahim

الاقتباسات الببليوغرافية

APA

Manal Awad Mohammed Ibrahim و Abdelbagi Osman Elsiddig Mustafa . (2013). Energy Optimization and Retrofit of Heat Exchanger Networks Case Study: Preheat-Train of the Crude Distillation Unit. أطروحة(رسائل ماجيستير). كلية الهندسة والتكنولوجيا-جامعة الجزيرة. السودان.

MLA

Manal Awad Mohammed Ibrahim و Abdelbagi Osman Elsiddig Mustafa . Energy Optimization and Retrofit of Heat Exchanger Networks Case Study: Preheat-Train of the Crude Distillation Unit. 2013. كلية الهندسة والتكنولوجيا-جامعة الجزيرة، رسائل ماجيستير.