The Accuracy of Multiple Sonographic Parameters in Estimation of Fetal Weight in Pregnant Sudanese Women Presenting to the Ribat University Hospital, Khartoum (December 2003 – May 2004).
Abdel Latief Ashmaig , Edwin Zozimo Ogo Jiribi
كلية الدراسات العليا-جامعة الخرطوم · السودان
الموضوعات
طب
الملخص
Ultrasonography has proved to be an accurate, safe, fast, reliable and costeffective imaging modality for the estimation of fetal weight at term.This study was carried out at the Ribat university hospital at Burri,Khartoum from December 6, 2003 to May 3, 2004 to evaluate the relativeaccuracy of three ultrasonographic formulas in estimating fetal weight interm Sudanese ladies.200 pregnant ladies, aged between 18 and 42 years, were examinedsonologically by a senior radiologist using an Aloka SSD- 650 real timescanner and the fetal weights were calculated using the Aloka formula A,Aoki’s formula and Shephard’s formula.36.5 % of the study population were primigravidas and the rest were parouswomen. The mean gestational age at delivery was 39.5 ± 1.4 weeks while11.5 % of the deliveries occurred after more than 40 weeks of gestation (post term)41.0 % of the ladies delivered on the same day of sonological examination,45.0 % delivered one day after examination while 14.0 % delivered two daysafter examination.The study found that the birth weights of 93.0 % of the newborn babies werewithin the reference weight of 2500 – 4000 grams. Only 4.0 % of thenewborns have low birth weights ( below the 10th percentile) while 3.0 %were macrosomic ( above 90th percentile).54.5 % of the newborn babies were of male gender compared with 45.5 %female babies.The mean birth weight for the study population was found to be 3196.70 ±454.16 grams. Male newborns had a higher mean birth weight (3281 ±664.308 grams) compared to newborn girls whose mean birth weight was3107 ± 635.077 grams.Two of the evaluated formulas, Aoki’s and Shephard’s formuals tended tounderestimate fetal weights while the third formula, the Aloka formula gaveestimates higher than the mean actual birth weight. However, all threeevaluated formulas were found to be accurate for estimation of fetal birthweight in Sudanese ladies. The Aoki formula had the highest degree ofaccuracy with 77.0 % of its estimates falling within 10.0 % of actual birthweights. The Shephard equation was next with 76.0 % of its estimates within10.0 % of actual birth weighs while Aloka’s equation predicted 75.5 % ofthe fetal weights within 10.0 % of actual birth weights. The Aoki formulaalso had the smallest mean error among the three evaluated formulas and hasbeen recommended for use by the Sudanese obstetricians.
روابط وملفات
التعريف والنوع
- رقم الوثيقة
- fc83f0a3-00ab-4cf9-be9f-6ddd91901220
- رقم العقد
- 0
- نوع الوسائط
- Crawler
- نوع المحتوى
- الرسائل العلمية
- صيغة المصدر
- رسائل ماجيستير
- نوع الملف
- pdf image
- أسماء الملفات
- fc83f0a3-00ab-4cf9-be9f-6ddd91901220_1.pdf
بيانات النشر
- ألقاب المؤلفين
- [{"name_ar":"Abdel Latief Ashmaig ","title_ar":"اشراف","title_en":"Supervision"},{"name_ar":"Edwin Zozimo Ogo Jiribi ","title_ar":"اعداد","title_en":"Preparation"}]
- اللغة
- English
المصدر والدورية
- اسم المصدر
- The Accuracy of Multiple Sonographic Parameters in Estimation of Fetal Weight in Pregnant Sudanese Women Presenting to the Ribat University Hospital, Khartoum (December 2003 – May 2004).
المحتوى والصفحات
- عدد الصفحات
- 0
إشراف وإعداد
- الإشراف
- Abdel Latief Ashmaig
- الإعداد
- Edwin Zozimo Ogo Jiribi
الاقتباسات الببليوغرافية
APA
MLA