Schoobrary رجوع
العودة إلى البحث
رسائل ماجيستير الانجليزية 2014 eb59bf2f-1664-4650-a6fb-24d964632c76

Characterization of Tannery Wastewater in Sudan University of Science and Technology

وصف المخلفات المائية للمدبغة في جامعة السودان للعلوم والتكنولوجيا

إسلام بكري إبراهيم أحمد, علي النعيم موسى, محمد عثمان بابكر

كلية الهندسة والتكنولوجيا-جامعة الجزيرة · السودان

الموضوعات

علوم بحتة وطبيعية

الملخص

The leather industry is suffering from the negative impact generated by the pollution it causes to the environment. Nearly 70% of the emission loads of BOD, COD, and Total Dissolved Solids (TDS) are generated from soaking, liming, degreasing, pickling and tanning process. There is an enormous pressure from the various pollution control bodies to regulate and minimize the amount of pollution generated from the leather processing. The need for use of alternative to chemical methods to combat pollution problem have become necessary to protect the industry and to comply with the environmental norms. In the present study, effluent samples were collected from a tannery in Khartoum-Sudan. The effluent samples were collected from the all stages of processing viz soaking, liming, deliming, pickling, Chrome tanning and Retanning. The physicochemical parameters of the tannery effluent viz, pH, alkalinity, acidity, biochemical oxygen demand (BOD5), chemical oxygen demand (COD), total solids (TS), total dissolved solids (TDS), suspended solids (SS), chlorides and sulfides were determined. All the parameters included in this study are found to be higher than the prescribed discharge limits for tannery industries. The investigation of the tannery wastewater from different tanning processes gave a number of conclusions. Results of the analysis showed that the pH of the tannery wastewater from different tanning processes viz. soaking, liming and unhairing, deliming and bating, pickling, chrome tanning and retanning: 7.50, 12.50, 8.80, 2.8, 3.50 and 4.5 respectively. Results of the analysis showed that the BOD5 of the tannery wastewater from different tanning processes viz. soaking, liming and unhairing, deliming and bating, pickling, chrome tanning and retanning: 1850±50, 7500±150, 2500±120,600±50, 650±50 and 1450±50 mg/l respectively. Results of the analysis showed that the COD of the tannery wastewater from different tanning processes viz. soaking, liming and unhairing, deliming and bating pickling, chrome tanning and retanning: 4600±150, 18600±150, 6300±150, 1550±50, 1700±50 and 3650±50 mg/l respectively. Results of the analysis showed that the total solids of the tannery wastewater from different tanning processes viz. soaking, liming and unhairing, deliming and bating, pickling, chrome tanning and retanning: 45000±1500, 36000±1500, 9000±500, 52000±1500, 46000±1500 and 12000±1500 mg/l respectively. Results of the analysis showed that the total dissolved solids of the tannery wastewater from different tanning processes viz. soaking, liming and unhairing, deliming and bating, pickling, chrome tanning and retanning: 36500±1500, 25000±1500, 5800±500, 49500±1500, 44000±1500 and 10500±1500 mg/l respectively. Results of the analysis showed that the suspended solids of the tannery wastewater from different tanning processes viz. soaking, liming and unhairing, deliming and bating, pickling, chrome tanning and retanning: 8500±500, 9000±500, 3200±500, 2500±500, 2000±500 and 1500±500 mg/l respectively. Results of the analysis showed that the chlorides level of the tannery wastewater from soaking, and pickling: 19250±1500, 23500±1500 mg/l respectively. Results of the analysis showed that the sulfide level of the tannery wastewater from liming and unhairing process is 380±50 mg/l. Results of the analysis showed that the alkalinity of the tannery wastewater from different tanning processes viz. soaking, liming & unhairing, and deliming& bating : 2500±500, 17500±500 and 12000±500 mg/l respectively. Results of the analysis showed that the acidity of the tannery wastewater from different tanning processes viz. s pickling, chrome tanning and retanning: 3500±100, 2500±100 and 2000±100 mg/l respectively. Reports indicate that the wastewaters from the tanneries do not satisfy the prescribed limits of the CPCB norms (1995).

التعريف والنوع

رقم الوثيقة
eb59bf2f-1664-4650-a6fb-24d964632c76
رقم العقد
0
نوع الوسائط
Crawler
نوع المحتوى
الرسائل العلمية
صيغة المصدر
رسائل ماجيستير
نوع الملف
pdf text
أسماء الملفات
72898_1.pdf

بيانات النشر

ترجمة العنوان
وصف المخلفات المائية للمدبغة في جامعة السودان للعلوم والتكنولوجيا
ألقاب المؤلفين
[{"name_ar":"إسلام بكري إبراهيم أحمد","title_ar":"اعداد","title_en":"Preparation"},{"name_ar":"علي النعيم موسى","title_ar":"اشراف","title_en":"Supervision"},{"name_ar":"محمد عثمان بابكر","title_ar":"اشراف","title_en":"Supervision"}]
اللغة
English

المصدر والدورية

اسم المصدر
Characterization of Tannery Wastewater in Sudan University of Science and Technology

المحتوى والصفحات

عدد الصفحات
0

إشراف وإعداد

الإشراف
علي النعيم موسى, محمد عثمان بابكر
الإعداد
إسلام بكري إبراهيم أحمد

الاقتباسات الببليوغرافية

APA

إسلام بكري إبراهيم أحمد،علي النعيم موسى و محمد عثمان بابكر. (2014). Characterization of Tannery Wastewater in Sudan University of Science and Technology. أطروحة(رسائل ماجيستير). كلية الهندسة والتكنولوجيا-جامعة الجزيرة. السودان.

MLA

إسلام بكري إبراهيم أحمد،علي النعيم موسى و محمد عثمان بابكر. Characterization of Tannery Wastewater in Sudan University of Science and Technology. 2014. كلية الهندسة والتكنولوجيا-جامعة الجزيرة، رسائل ماجيستير.