Schoobrary رجوع
العودة إلى البحث
رسائل ماجيستير الانجليزية 2012 0eccd182-c5f4-49ff-9876-568423fceda6

Full Scale-Low Computational Cost Virtual CFD Model To Predict the Performance Of A10 Ton Roof-Top Ac Unit

إياد أنور فيصل, فضل مقلد

كلية مارون سمعان للهندسة والعمارة-الجامعة الأمريكية في بيروت · لبنان

الموضوعات

علوم تطبيقية وتكنولوجية

الملخص

This thesis extends the work of Moukalled et al. [1] for predicting the performance of a roof-top air conditioning unit using CFD codes. Recently, Moukalled et al. [1] studied numerically the thermal and hydrodynamic characteristics of an AC packaged unit by investigating the air zone separately and considering the condensation of water vapor at the evaporator coil surface. This step was considered a recent work and was not adopted by previous researchers. However, in this thesis, a novel contribution is considered by integrating the refrigerant cycle simultaneously with the air flow thus, the coil temperature and heat transfer characteristics are simulated and obtained with the solution prediction. The model is defined as a conjugate heat transfer problem and accounts for predicting simultaneously the thermal and hydrodynamic characteristics of air and refrigerant flow streams. A conformal mesh was generated at the common interface regions separating fluid and solid zones to account for the continuity of heat fluxes at these interfaces. In addition to the condensation phenomenon that occurs at the coil surface, the evaporation of refrigerant is adopted inside the coil circuits. Therefore, the Mixture Model with multi-species transfer was employed to achieve this issue. Due to the limited availability in computational power and the enormous need of physical memory to adopt this situation, only 5 refrigerant circuits were considered in the simulation. For this reason, the physical model was reconstructed to maintain the same flow pattern in the original unit. A sensitivity analysis was then considered based on varying specific thermal and hydrodynamic conditions of air at the unit inlet section. The aim was to assess the robustness and validity of the CFD model applied on the considered physical domain. The model was simulated on an 8 core machine, and the physical memory required was 28 GB out of 31 GB available. The simulated CFD models were compared with experimental data in the literature for validation purp

التعريف والنوع

رقم الوثيقة
0eccd182-c5f4-49ff-9876-568423fceda6
رقم العقد
0
نوع الوسائط
Crawler
نوع المحتوى
الرسائل العلمية
صيغة المصدر
رسائل ماجيستير
نوع الملف
pdf text
أسماء الملفات
1636239_1.pdf

بيانات النشر

ألقاب المؤلفين
[{"name_ar":"إياد أنور فيصل","title_ar":"اعداد","title_en":"Preparation"},{"name_ar":"فضل مقلد","title_ar":"اشراف","title_en":"Supervision"}]
اللغة
English

المصدر والدورية

اسم المصدر
Full Scale-Low Computational Cost Virtual CFD Model To Predict the Performance Of A10 Ton Roof-Top Ac Unit

المحتوى والصفحات

عدد الصفحات
0

إشراف وإعداد

الإشراف
فضل مقلد
الإعداد
إياد أنور فيصل

الاقتباسات الببليوغرافية

APA

إياد أنور فيصل و فضل مقلد. (2012). Full Scale-Low Computational Cost Virtual CFD Model To Predict the Performance Of A10 Ton Roof-Top Ac Unit. أطروحة(رسائل ماجيستير). كلية مارون سمعان للهندسة والعمارة-الجامعة الأمريكية في بيروت. لبنان.

MLA

إياد أنور فيصل و فضل مقلد. Full Scale-Low Computational Cost Virtual CFD Model To Predict the Performance Of A10 Ton Roof-Top Ac Unit. 2012. كلية مارون سمعان للهندسة والعمارة-الجامعة الأمريكية في بيروت، رسائل ماجيستير.