رسائل ماجيستير
العربية
2014
04399a29-d357-457a-9070-606863d39dcb
تأثير التعقيم بأشعة المايكروويف في قوة ارتباط مادتي تبطين صلبتين ذاتيتي التصلب مع أكريل قواعد التعويضات السنية المتحركة: دراسة مخبرية
The Effect of Microwave Disinfection on Bond Strength of Two Hard Chairside Denture Reline Materials with Acrylic Denture Base: In Vitro Study
رجوي عبود المنلا, محمد أحمد غريواتي, محمد رائد عرب
كلية طب الأسنان-جامعة حلب · سوريا
الموضوعات
طب
روابط وملفات
التعريف والنوع
- رقم الوثيقة
- 04399a29-d357-457a-9070-606863d39dcb
- رقم العقد
- 0
- نوع الوسائط
- Crawler
- نوع المحتوى
- الرسائل العلمية
- صيغة المصدر
- رسائل ماجيستير
- نوع الملف
- pdf text
- أسماء الملفات
- 1966010_1.pdf
بيانات النشر
- ترجمة العنوان
- The Effect of Microwave Disinfection on Bond Strength of Two Hard Chairside Denture Reline Materials with Acrylic Denture Base: In Vitro Study
- ألقاب المؤلفين
- [{"name_ar":"رجوي عبود المنلا","title_ar":"اعداد","title_en":"Preparation"},{"name_ar":"محمد أحمد غريواتي","title_ar":"اشراف","title_en":"Supervision"},{"name_ar":"محمد رائد عرب","title_ar":"اشراف","title_en":"Supervision"}]
- اللغة
- Arabic
المصدر والدورية
- اسم المصدر
- تأثير التعقيم بأشعة المايكروويف في قوة ارتباط مادتي تبطين صلبتين ذاتيتي التصلب مع أكريل قواعد التعويضات السنية المتحركة: دراسة مخبرية
المحتوى والصفحات
- عدد الصفحات
- 90
- ترجمة الملخص
- Microwave radiation is considered one of the best methods used in sterilization ,and newly This method is used to sterilize Removable Prosthodontics, but will this method have effect on Bond Strengths of Two Hard Chairside Denture Reline Materials with Acrylic Denture Base .The aim of study: The Effect of Microwave Disinfection on Bond Strength of Two Hard Chairside Denture Reline Materials with Acrylic Denture Base before and after bond. Materials and Methods :This study examined the use of Two Hard Chairside Denture Reline Material and distributed according to samples classified in to (3) main groups in addition to the control group (for each material), the first one set sterilize before bonding with the lining materials for one month three times per week and then connects with the lining materials, the second group was sterilized after connecting for a month three times per week, while the latter group was sterilized before and after bonding for one month three times per week, and the applied forces in samples were measured in each group and compared with the control group that was not sterilized(not exposed to microwave radiation).Results In both reline material group(B)outperformed all groups, while statistically there was no significant difference between (C) & (D) groups. Conclusions :sterilization microwave effect on Bond Strength between the lining materials with acrylic denture bases was negative.
- كلمات الباحثين
- Hard chairside reliner, High impact acryl, Microwave sterilization, الإكريل المقاوم للكسر, التبطين الصلب ذاتي التصلب, التعقيم بأشعة المايكروويف
إشراف وإعداد
- الإشراف
- محمد أحمد غريواتي, محمد رائد عرب
- الإعداد
- رجوي عبود المنلا
الاقتباسات الببليوغرافية
APA
رجوي عبود المنلا،محمد أحمد غريواتي و محمد رائد عرب. (2014). تأثير التعقيم بأشعة المايكروويف في قوة ارتباط مادتي تبطين صلبتين ذاتيتي التصلب مع أكريل قواعد التعويضات السنية المتحركة: دراسة مخبرية. أطروحة(رسائل ماجيستير). كلية طب الأسنان-جامعة حلب. سوريا.
MLA
رجوي عبود المنلا،محمد أحمد غريواتي و محمد رائد عرب. تأثير التعقيم بأشعة المايكروويف في قوة ارتباط مادتي تبطين صلبتين ذاتيتي التصلب مع أكريل قواعد التعويضات السنية المتحركة: دراسة مخبرية. 2014. كلية طب الأسنان-جامعة حلب، رسائل ماجيستير.