Schoobrary رجوع
العودة إلى البحث
رسائل ماجيستير العربية 2017 029571b7-c756-4c80-9f96-43e449c13bb7

تأثير تغير نسب استبدال الحصويات البيتونية المدورة RCA على خصائص الخلطات الإسفلتية الساخنة (HMA)

The Impact of Changing Substitution Proportions of Recycled concrete aggregate (RCA) on Characteristics of Hot Mix Asphalt (HMA)

رباب جوني, مناف علي الخضر

كلية الهندسة المدنية-جامعة دمشق · سوريا

الموضوعات

علوم تطبيقية وتكنولوجية

التعريف والنوع

رقم الوثيقة
029571b7-c756-4c80-9f96-43e449c13bb7
رقم العقد
0
نوع الوسائط
Crawler
نوع المحتوى
الرسائل العلمية
صيغة المصدر
رسائل ماجيستير
نوع الملف
pdf text
أسماء الملفات
1961433_1.pdf

بيانات النشر

ترجمة العنوان
The Impact of Changing Substitution Proportions of Recycled concrete aggregate (RCA) on Characteristics of Hot Mix Asphalt (HMA)
ألقاب المؤلفين
[{"name_ar":"رباب جوني","title_ar":"اشراف","title_en":"Supervision"},{"name_ar":"مناف علي الخضر","title_ar":"اعداد","title_en":"Preparation"}]
اللغة
Arabic

المصدر والدورية

اسم المصدر
تأثير تغير نسب استبدال الحصويات البيتونية المدورة RCA على خصائص الخلطات الإسفلتية الساخنة (HMA)

المحتوى والصفحات

عدد الصفحات
85
ترجمة الملخص
Most of studies and scientific researches have recently focused on the possibility of using recycled concrete aggregate (RCA) (resulting from recycling building demolition waste) to produce hot mix asphalt (HMA) for roads. The percentage of (RCA) in these studies varied in accordance with the case of study and standards.This research has been carried out as a try to find the highest possible ratio of (RCA) aggregates to produce hot asphalt mix, by using fine aggregate gradation (gradation 2 of wearing course) in accordance with the Syrian technical limits and specifications in 2002,for fine aggregate gradation (laboratories waste) which have the same values of cement standards and cubic resistance.At first a 60% RCA asphalt mix had been designed according to Marshall's method, and it was accepted. After that a 75% RCA asphalt mix had been studies, but voids in mineral aggregates ratio was not accepted. That's why the effect of changing Mrashall compaction energy on gradation's curve of this mix had been chosen to study.The results of this study have showed that 60%RCA can be used for heavy traffic roads, and the optimum asphalt binder was 6.3%. While 75% RCA cannot be used in any of light, medium or heavy traffic roads, because the three Marshall compaction energies (75,50,35 blows) all of them caused of going the gradation curve outside the allowable area adopted in this study.
كلمات الباحثين
asphalt mixture, Building demolition products, Marshall test, Recycled concrete aggregate, اختبار مارشال, حصويات بيتونية معاد تدويرها, خلطة اسفلتية, نواتج هدم المباني

إشراف وإعداد

الإشراف
رباب جوني
الإعداد
مناف علي الخضر

الاقتباسات الببليوغرافية

APA

رباب جوني و مناف علي الخضر. (2017). تأثير تغير نسب استبدال الحصويات البيتونية المدورة RCA على خصائص الخلطات الإسفلتية الساخنة (HMA). أطروحة(رسائل ماجيستير). كلية الهندسة المدنية-جامعة دمشق. سوريا.

MLA

رباب جوني و مناف علي الخضر. تأثير تغير نسب استبدال الحصويات البيتونية المدورة RCA على خصائص الخلطات الإسفلتية الساخنة (HMA). 2017. كلية الهندسة المدنية-جامعة دمشق، رسائل ماجيستير.