رسائل ماجيستير
العربية
2014
00f9b8fe-59e0-4632-9082-4c1f2ded6359
دراسة مقارنة لتأثير رقائق الـ Adapta وطريقة التشميع التقليدية على الثبات ودقة الانطباق الحفافي للقلنسوات المعدنية: دراسة مخبرية
A Comparative Study of the Effect of Adapta Foils and Traditional waxing Method on the Retention and Marginal Fit of the Metal Framework: in vitro study
جاد الكريم القدور, خير الدين طرشة كردي, يامن بشنقلي
كلية طب الأسنان-جامعة حلب · سوريا
الموضوعات
طب
روابط وملفات
التعريف والنوع
- رقم الوثيقة
- 00f9b8fe-59e0-4632-9082-4c1f2ded6359
- رقم العقد
- 0
- نوع الوسائط
- Crawler
- نوع المحتوى
- الرسائل العلمية
- صيغة المصدر
- رسائل ماجيستير
- نوع الملف
- pdf text
- أسماء الملفات
- 1965990_1.pdf
بيانات النشر
- ترجمة العنوان
- A Comparative Study of the Effect of Adapta Foils and Traditional waxing Method on the Retention and Marginal Fit of the Metal Framework: in vitro study
- ألقاب المؤلفين
- [{"name_ar":"جاد الكريم القدور","title_ar":"اشراف","title_en":"Supervision"},{"name_ar":"خير الدين طرشة كردي","title_ar":"اشراف","title_en":"Supervision"},{"name_ar":"يامن بشنقلي","title_ar":"اعداد","title_en":"Preparation"}]
- اللغة
- Arabic
المصدر والدورية
- اسم المصدر
- دراسة مقارنة لتأثير رقائق الـ Adapta وطريقة التشميع التقليدية على الثبات ودقة الانطباق الحفافي للقلنسوات المعدنية: دراسة مخبرية
المحتوى والصفحات
- عدد الصفحات
- 103
- ترجمة الملخص
- Introduction:Die-spacing is a technique commonly used to provide space for cement.The provision of a cement space between the internal surface of the crown and the prepared tooth surface may affect the important clinical factors of crown seating and retention.Purpose: A comparative study for the effect of the Adapta foils and the traditional waxing method on the retention and marginal fit of the metal framework.Materials and methods:60 mandibular premolars were prepared and divided into 2 group. The impression was made with silicon and working models were produced. A total of 60 wax pattern fabricated with two different technique: Adapta foils method and die spacer method. The metal frameworks were fabricated and cemented on their prepared teeth using glass ionomer cement. Finally the marginal gap was measured by a stereo microscope,and thenall experimental teeth were subjected to a universal testing machine to evaluate the retention value.Results:The adapta foils group showed more marginal fit (40.19μ) than die spacer group (99.35μ),and The removal force increased from 290.8 N (Die spacer) to 364.5 N (Adapta).Conclusions:Using of adapta foils will enhance the marginal fit and increase the retention value of metal frame work.
- كلمات الباحثين
- Adapta foils, die spacer, marginal fit, wax pattern method
إشراف وإعداد
- الإشراف
- جاد الكريم القدور, خير الدين طرشة كردي
- الإعداد
- يامن بشنقلي
الاقتباسات الببليوغرافية
APA
جاد الكريم القدور،خير الدين طرشة كردي و يامن بشنقلي. (2014). دراسة مقارنة لتأثير رقائق الـ Adapta وطريقة التشميع التقليدية على الثبات ودقة الانطباق الحفافي للقلنسوات المعدنية: دراسة مخبرية. أطروحة(رسائل ماجيستير). كلية طب الأسنان-جامعة حلب. سوريا.
MLA
جاد الكريم القدور،خير الدين طرشة كردي و يامن بشنقلي. دراسة مقارنة لتأثير رقائق الـ Adapta وطريقة التشميع التقليدية على الثبات ودقة الانطباق الحفافي للقلنسوات المعدنية: دراسة مخبرية. 2014. كلية طب الأسنان-جامعة حلب، رسائل ماجيستير.