The ergonomic benefits of a laterallytilted operating room table and frictionreducing devices when laterally transferring patients to a stretcher
Adnan Hassan El Tannir , Saif Al-Qaisi
كلية مارون سمعان للهندسة والعمارة-الجامعة الأمريكية في بيروت · لبنان
الموضوعات
علوم تطبيقية وتكنولوجية
الملخص
A commonly performed task among nurses is the lateral transfer of patients from one surface to another, such as an operating room (OR) table, stretcher, and-or hospital bed. This task exposes nurses to substantial biomechanical loads due to the posture adopted and the weight handled during the task. Therefore, this research is proposing and testing an alternative method for performing lateral transfers that is hypothesized to reduce the biomechanical loading on nurses. The objective of this study is to investigate the ergonomic benefits of using a laterally tilting OR table and friction-reducing devices (FRD) during lateral transfer tasks. Sixteen nursing students and sixteen college students, who acted as patients, were recruited for this study. Two table angles were evaluated: a flat OR table and a laterally tilted OR table. During the latter case, the nurse continually tilts the table laterally using a remote control as the patient slides to the adjacent surface with an additional nurse guiding the transfer. At both bed angles, three FRDs were considered: a sliding board, a plastic bag, and a bed sheet. Biomechanical loading of the nurse at the neck, shoulders, and back were be assessed using an electromyography (EMG) device. After each experimental trial, the nurses were asked to rate their perceived level of physical exertion on the Borg-CR10 scale. The efficiency of each method was measured using a stop watch. Preliminary results favored the laterally tilting OR table over the flat OR table, showing a reduction in muscle loading and perceived physical exertion. By using the laterally tilting OR table with FRD, muscle activity was reduced by 70.5percent at the upper trapezius, 53.3percent at the latissimus dorsi, 15.7percent at the lumbar erector spinae, and 48.8percent at the posterior deltoid. The advantage of the proposed method is that: it involves no investment (since OR tables already have the feature to laterally tilt); it reduces biomechanical loading and perceived physical exertion; and it is relatively efficient.
روابط وملفات
التعريف والنوع
- رقم الوثيقة
- 004fa4b7-3997-4dda-9f33-0e29cde74e01
- رقم العقد
- 0
- نوع الوسائط
- Crawler
- نوع المحتوى
- الرسائل العلمية
- صيغة المصدر
- رسائل ماجيستير
- نوع الملف
- pdf text
- أسماء الملفات
- 1632607_1.pdf
بيانات النشر
- ألقاب المؤلفين
- [{"name_ar":"Adnan Hassan El Tannir ","title_ar":"اعداد","title_en":"Preparation"},{"name_ar":"Saif Al-Qaisi","title_ar":"اشراف","title_en":"Supervision"}]
- اللغة
- English
المصدر والدورية
- اسم المصدر
- The ergonomic benefits of a laterallytilted operating room table and frictionreducing devices when laterally transferring patients to a stretcher
المحتوى والصفحات
- عدد الصفحات
- 0
- كلمات الباحثين
- American University of Beirut. Medical Center. Electromyography.$Human engineering.$Nurses -- Lebanon.$Muscles -- Diseases.
إشراف وإعداد
- الإشراف
- Saif Al-Qaisi
- الإعداد
- Adnan Hassan El Tannir
الاقتباسات الببليوغرافية
APA
MLA